Diethanol Amine Supplier and Manufacturer

Diethanol Amine

Description
Produced water discharge throughout the world is regulated to ensure that minimal oil enters our oceans and waterways. Effluent water from production separators typically contains 100 – 800ppm oil, depending on the effectiveness of the separator, demulsifier and residence time of the system. Some operators set their own standard to 10 ppm. It is therefore necessary to ensure that the oil in water emulsion, which remains after crude oil and water separation, is resolved prior to overboard discharge. In addition, if produced water is to be re-injected into the reservoir it is important that any solids present are removed in this water treatment stage.

In general, operators achieve destabilization of oil in water emulsions through a combination of mechanical and chemical means:
Industrial hydrocyclones, centrifuges, flotation units
Deoiler chemicals
Both mechanical and chemical methods aim to coalesce the oil suspended in the water by either flocculation of the oil droplets (grouping the oil droplets in to a loose association) or coagulation of the oil droplets (making the size of the droplets bigger).


Characteristic and Property

Physical Appearance: The Material shall be a clear, homogenous liquid, free from visible impurities.
Solubility in Distilled Water…………………………………………………Soluble in water in all proportions
Flash Point, °C………………………………………………………………50 (Minimum).
Relative density at 20 °C/ 20 °C …………………………………………1.090 to 1.096 .
Moisture content,    percent by mass ………………………………………98.0 (Minimum).
Di-Ethanol Amine Content,    percent by Mass ……………………………25 (Minimum) .
Crystallizing Point, °C ………………………………………………………25 (Minimum) .
Colour,    Hazen units …………………………………………………………25 (Maximum).

Note: Detailed specifications which includes performance test are available on request.

Advantages

Deoiler chemicals are applied dependant on whether water is discharged directly overboard or whether the produced water is collected in slop tanks prior to discharge. If water is discharged directly, then chemical addition would normally be downstream of separation and upstream of any water treatment vessels. If water is retained in slops tanks prior to discharge then chemical addition would generally be downstream of water treatment vessels and prior to slops. 
Field experience has shown that typical dose rates for the Deoiler products are between 5 - 25 ppm after field optimization.

Toxicity and Handling

It can be stored in closed containers away from direct sunlight at ambient temperature. During handling, direct contact with human body is to be avoided. Safety goggles and gloves are recommended for safe handling.

Packaging and Storage

Products can be supplied in 210 liter drums and as per buyer requirement.

This Material is supplied solely for informational purposes and UNIVERSAL makes no guarantees or warranties, either expressed or implied, with respect to the accuracy or use of this data. All product warranties and guarantees shall be governed by the Standard Terms of Sale.

Our Products